Q. What is the difference between USB communication and infrared communication?
A. USB communication refers to communication using a USB cable connected between the USB terminal of a personal computer and the communication unit. Infrared communication refers to wireless communication using an infrared terminal of a personal computer and the infrared terminal of the watch. Cyber Aqualand Nx is compatible with both types of communication.


Q. Can I use a USB hub?
A. Yes, you can. But because it is up to HUB that you use, some types of USB hub may not be used.


Q. Something wrong with USB communication system. What happened?
A. Please check the following matters.
=> Isn't watch in Low power mode?
> Take out the watch from the communication unit then press A and D button simultaneously for more than 2 seconds. After the watch is switched to standard mode, attach the watch to the communication unit.
Please try transferring data after the watch face turns to the USB communication display.
=> Is the USB cable connected to PC and the communication unit?
> Connect the USB cable correctly.
=> Is a USB driver installed?
> If not, install PgmUSB Device.
=> Does PgmUSB Device have the "x" mark under Control panel - System - Device manager?
> If the "x" mark is checked, delete PgmUSB Device, then install it again.
=> Does your PC have OHCI (Open Host Controller Interface) type?
> With OHCI type USB controller, some communication errors occur because of the combination problem. In this case, use a USB controller of UHCI (Universal Host Controller Interface) type or infrared communication. (You can check the type of the controller with the System Property.)

If you cannot solve your problem even after reading above answers, please consult CITIZEN SERVICE CENTER.


Q. How long is the possible communication distance of the infrared communication function?
A. The maximum distance is 15cm with directivity margin of about +/-15 degree.


Q. What is the transmission rate of infrared communication and USB communication?
A. The maximum trasmission rate of both infrared communication and USB communication is 57.6kbps.


Q. Is the communication unit compatible with USB 2.0?
A. Yes, the communication unit can operate with the USB 2.0 interface, but the transfer rate is the same as that of USB 1.1.


Q. Can I use Cyber Aqualand Nx to communicate with a cell phone or PDA?
A. No, you cannot.
Click here to see the Aqualand Graph Nx operating environment.


Q. I cannot download the logs from the watch to PC using IrDA USB adapter. Why?
A. Please install an appropriate driver for the adapter.


Q. Watch does not switch to Infrared Communication Mode.
A. Watch may be insufficiently charged. Please check the IrDA status in the System Monitor Mode. If IrDA is "NG", please charge the watch.
Communicating Between PC and Watch
Q. Can I transfer log data of a personal computer into the watch?
A. No, you cannot.


Q. I cannot load log data from the watch to PC.
A. The possible causes are as follows.
> There is no logs in your watch.
> USB cable is not connected (when communicating with USB).
> The watch is not connected to the communication unit properly.
> Selecting wrong interface with the <Interface> dialogue in Aqualand Graph Nx.


Q. I cannot load log data from the watch to PC(through USB).
A. The possible causes are as follows.
=> A USB driver is not installed.
> Install a USB driver.


Q. I cannot load log data from the watch to PC. (with Infrared communication)
A. The possible causes are as follows.
=> An Infrared communication driver is not installed in your PC.
> Install an Infrared communication driver.
=> Your PC does not have an Infrared transmitter/receiver.
> Please use USB communication.
=> The watch is not directed right to the Infrared transmitter/receiver of your PC.
> The maximum communication distance between the transmitter and receiver is 15cm and the effective transmission angle is +/-15 degrees.
=> The watch moves away from the Infrared transmitter/receiver during communication.
> The maximum communication distance between the transmitter and receiver is 15cm and the effective transmission angle is +/-15 degrees. Observe this range.
=> The watch is not in the Infrared communication mode.
> Press and hold the D button for at least 2 seconds in any mode, and the watch is set in the infrared communication mode. Then, push the C button to select "toPC".
=>The infrared port is disabled in Device Manager in the Controla Panel of your computer.
> Enable the infrared port.
=>The communication speed is set faster than 57.6kbps.
> Set the communication speed less than 57.6kbps with infrared device driver. Please refer to the instruction manual of your perosnal computer or infrared adapter for information.


Q. An error message, "Failed to connect with watch" is displayed after starting the transfer.
A. Select the right interface in the interface setting of the Aqualand Graph Nx program.
1. an error message

2.Interface setting: Select the right interface.

Communication between watches


Q. What can I communicate between watches?
A. You can communicate the current time, Alarm time and sound, Dive Alarm depth and time, and Anniversaries graphics.


Q. What is going to happen if the Anniversary which has the same date as the previously set in my watch is transferred?
A. The transferred Anniversary is written over the previously set anniversary. Please make sure it does not happen.